0
Sie haben keine Artikel im Warenkorb.

0

The New IsoMist XR - Extended Range Programmable Temperature Spray Chamber

- Enhanced Performance for ICP-MS and ICP-OES

The IsoMist XR programmable temperature-controlled cyclonic spray chamber now features an improved thermodynamic design
providing an extended temperature range and faster cool-down so your ICP application is ready to go sooner.

The IsoMist XR is a compact, convenient and maintenance-free temperature-controlled sample introduction system for all ICP-OES and ICP-MS.

For the Application Note:"Improved Performance with Precise Temperature Control for any ICP Application".

Improve Analytical Stability

On the IsoMist XR, the spray chamber temperature is accurately controlled through an improved thermodynamic design using a multi-stage Peltier device.
The spray chamber temperature is settable in 1°C increments from -25°C to 80°C guaranteeing optimum conditions for any application.
The improved cooling efficiency of the new multi-stage Peltier design means the IsoMist XR is ready, sooner and the cool-down time is reduced.

Reduce Oxide Formation in ICP-MS

Using the IsoMist XR spray chamber at sub-ambient temperature on an ICP-MS, the sample is cooled so less water vapor is transferred to the plasma resulting in lower oxide formation and reduced polyatomic interferences - improving accuracy and detection limits.

Perfect for Volatile Organics

When analyzing volatile organic solvents such as naphtha and gasoline a lower sample introduction system temperature reduces nebulization efficiency avoiding quenching of the plasma from solvent over-loading. With a minimum temperature of -25°C analyzing volatile organic solvents is even easier.

Constant Temperature Improves Analytical Stability

Fluctuations in the lab temperature affects sample viscosity and nebulization efficiency.
Maintaining the sample introduction at a constant and stable temperature improves analytical reproducibility, enhances throughput,
and lowers operating costs by reducing the need to re-run samples when a calibration verification check standard drifts outside the acceptable limits.

Enhance Sensitivity with Elevated Sample Introduction Temperatures

The sensitivity for many analyses is enhanced by running the spray chamber at an elevated temperature, which is particularly important for samples with limited volume.
A Spray Chamber Optimized for Performance

The IsoMist XR incorporates a proven Twister cyclonic spray chamber available in either glass, quartz, or PFA

- all with Helix, O-ring free, zero dead-volume nebulizer interface.

* Compared to a Scott-type spray chamber, cyclonic spray chambers are more sensitive and have better washout between samples.
The O-ring-free, Helix nebulizer interface eliminates sample contamination and ensures simple nebulizer removal and replacement for routine cleaning.
With a positive stop built-in, Helixtm ensures the correct and reproducible nebulizer insertion depth for consistent analytical performance.

Artikel 1 bis 20 von 100 gesamt

Seite:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5

Liste  Gitter 

  1. IsoMistXR Kit for Agilent 7500/7700
  2. KT-1010P-XR
  3. KT-1010Q-XR
  4. KT-1011-XR
  5. KT-1011P-XR
  6. KT-1011Q-XR
  7. KT-1012-XR
  8. KT-1012P-XR
  9. KT-1012Q-XR
  10. KT-1013-XR
  11. KT-1013P-XR
  12. KT-1013Q-XR
  13. KT-1014-XR
  14. KT-1014P-XR
  15. KT-1014Q-XR
  16. KT-1015-XR
  17. KT-1015P-XR
  18. KT-1015Q-XR
  19. KT-1017-XR
  20. KT-1017P-XR

Artikel 1 bis 20 von 100 gesamt

Seite:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5

Liste  Gitter